玖玖草在线视频观看,日韩在线96,亚洲天堂1,92超碰自拍,大干欧美女♀,成年人一区二区,999精品999精品,伊青青草视频,国产18区

You path:  Home >> NEWS >> Led tube - intsead of fluoresc...
Led tube - intsead of fluorescent tube in future
Mike  2012-07-17 14:56:40  

Led tube - intsead of  fluorescent tube in future.
Since 50 years before ,the  fluorescent tubes have  carried  the bulk of lighting in offices, factories and public buildings.
Everyone knows them - and got adjusted to its disadvantages.

A little Background of  traditional fluorescent tube :
  Traditional fluorescent tube is low-pressure Mercury vapor discharge lamp which produce by  UV light.
  The UV light hits the wall of the glass tube which is covered with Phosphor.
  The phosphor absorb the UV light and transforms it to visible white light sources .
  The tube needs high voltage to start the discharge, and a devide that limits the current during operation. Most  of  Flourescent  tubes have therefore a ballast and a starter, in new tube these functions can be performed by electronic circuits (more expensive).

The Main Disadvantages Of fluorescent Tube :
  If an Fluorescent  tube or CFL breaks, the whole building and its A/C ducts need to be cleaned. Only some of the energy lamps are  transformed to light. The rest is heat, UV and an unnatural light spectrum. The light is pulsing with the main frequency (50/60Hz). Especially when many tubes are connected to one power line, the light feels uncomfortable and may cause some  health problems.
  In  some buildings where there are  many  flourecsent tubes installed  the capacitive and inductive electricity waves will be unsynchronized. For more than 500 tubes, a special power control unit is needed to  be correct to deal  this problem..

  Due to  the glass of the tubes  breakage and leakage problems.Mor than  5%-10% of defective new fluorescent tubes are considered to be acceptable..
   An inductive kick from ballast provides a high voltage pulse to start the Fluorescent tubes. If the tube is frequently switched on and off, Both the energy savings of Fluorescent  tubes and CFL's are very limited.
On top of it, the tubes will age rapidly.

 

The best option : LED Tube
   A real option between to fluorescent lighting are LED Tube.
It contains absolutely no mercury, do not emit UV radiation and are really energy saving, lasting five times as long as fluorescent lamps ..
Characteristics of LED Tube  vs. Flourescent  tube

Environmental Advantage of LED Tube

  Less power consumption
  A LED tube consumes only about 30% of the power and  a Flourescent tube needs to produce an equivalent illumination
  No poisonous substances in LED tube 
  Flourescent tubes and CFL tube containt Mercury and argon  
  Recycling of LED tube is possible
  Flourescent  tube and CFL light are hazardous waste, can't be recycled;
  LED tube containts valuable raw materiale which can be re-used, for example , Aluminum, PC, etc.
  Carbon Dioxide
  Led tube saves about 2/3 of the greenhouse gas an Flouresent  tube would create more greenhouse gas .
  Long life time
  LED tube lives about 5 times as long as FL tube, 50,000 hours instead of 10 to 15,000.

LED tube is Directional
  While the flourescent tube and conventional light bulb distribute their light all around, LED tube  is directed to an angle of 120°. Luminaries are designed to shade off the non-useful portions.
E.G:
For a tube that illuminates a working area from above, only the fraction of the lamps  that hits the working area is useful. All  of other lamp is lost - radiated in other directions.
When comparing the lumen, The  Flourescent tube needs to produce much more light to achieve the same illumination on a flat surface.
Since in most cases 2/3 of the light of a Flourescent tube is lost that way, an LED tube only needs 1/3 of the lumens to achieve the same illumination.

Economy and High return on Investment (ROI)

  LED tube is expensive, more than 10 times the price than  Flourescent tube.
  A sides of the environmental advantages, LED tube return profits in the following way:
  Long operation hours
  where the power saving justify the higher price
  For example , the  Wal-mart is changing  all of the  Flourescent  tubes to cooled areas by LED tubes, ROI in half a year
  Frequent light switching
  Flourescent tubes doesn't like switching, their lifetime declines sharply with frequent switching
  For example : automatic staircase lights, elevator lights
  Difficult location
  where the charge of exchange is substantial?
  For example : high ceilings, factory lighting, outdoor advertising lights boxes / billboards etc.

[Print]  [Close]  

Copyright© Shenzhen Longtech Electronics Co., Ltd    led t8 tubes light, t8 led tube light,  t8 led tube lighting, led t5 tube light, led tube lights t5, t5 led tubes light, t10 led tube lights, t10 led tubes light Sitemap    LED Tube light,LED Tube lamp,LED Tube Light Manufacturer  

 
 
2503564770
 
375737297
 
ete6688523
 
??????????????
 
??????????????
 
 
台南县| 南陵县| 大丰市| 丰顺县| 旺苍县| 府谷县| 泸西县| 岳阳县| 东至县| 大同县| 平罗县| 宝丰县| 阜城县| 江安县| 诏安县| 图木舒克市| 诏安县| 容城县| 云梦县| 孝义市| 长宁县| 二连浩特市| 天峻县| 黄石市| 巍山| 罗山县| 探索| 京山县| 秀山| 合肥市| 海口市| 甘南县| 韶关市| 象山县| 雷州市| 子长县| 曲阜市| 延安市| 黑河市| 潢川县| 类乌齐县|